750W Variable Step-Down Converter

R895.00

Package Includes

  • 1x Display Module
  • 1x 750W Variable Step-Down Converter Power Module
  • 2x 200mm Ribbon Cable

Available on backorder

SKU: 8ME3009 Category: Tag:

Description

This constant voltage, constant current programmable DC-DC converter is not like all your traditional analog power supplies that are available nowadays. Its adjustable output voltage ranges from 0VDC to 60VDC, with 0.01V steps. While its adjustable output current ranges from 0A to 15A, with 0.01A steps. These 2 values are continuously updated on the full color 1.44 inch LCD display. Here you can also view the preset voltage, input voltage, output voltage, preset current, output current, output power, and on the output state reminder area you can see whether the output is ON or OFF, the state of constant voltage and constant current, if the output is normal or not, if the key is locked or not, and the current data groups that are being used.

On top of all this, the module has a power-down storage function that can store up to 10 different groups of preset values. Finally, on the setting data interface, you are able to adjust the over-voltage value, the over-current value, the over-power value, data set and LCD brightness. All in all a great little module which can be used in a wide range of applications.

Features / Specs

  • Module Type: DC-DC Buck / Step-Down Converter
  • Input Voltage: 6VDC – 60VDC
  • Output Voltage: 0V – 50V
  • Max Output Current: 15A
  • Max Output Power: 750W
  • Output Voltage Resolution: 0.01V
  • Output Current Resolution: 0.01A
  • Output Voltage Accuracy: ± (0.5% + 1 digit)
  • Output Current Accuracy: ± (0.5% + 2 digits)
  • Display Module Dimensions: 79mm x 43mm x 41mm (L x W x H)
  • Power Module Dimensions: 93mm x 71mm x 41mm (L x W x H)
  • Inter-connect Ribbon Cable Length: 200mm

Operating Instructions

When connect the power supply, the screen shows welcome window firstly and then comes into main interface. On the main interface, the output set voltage value and the output set current value is on the top of the screen. The big font value on the left are the current real output voltage, the current real output current and the current real output power. Input voltage is on the bottom of the screen. There are some running status icons on the right of the screen, key lock icon, abnormal output status icon, constant voltage and constant current icon, data set tip icon and opening or closing output icon.

Set the output voltage and output current on the main interface:
Press V/↑key shortly, you can enter into voltage setting status. Then press the coding potentiometer, and then enter to adjust the numerical value. Press coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. Turn by clockwise rotation to increase the numerical value; Turn by counterclockwise to decrease the numerical value. If you want to exit adjusting the numerical value, press shortly V/↑. In the same time the preset value will be stored. Or you can do nothing in one minute, the status will be automatically existed and the preset will be stored too. You can press A/↓to set the output current by the same way.

Set the data on the data setting interface:
On the main interface, you can press SET key shortly to enter into data setting interface. On the data setting interface, press shortly V/↑or A/↓ to page up or page down to U-SET or I-SET, and then set the output voltage and output current by same way used in the main interface.

Set the protection value:
Page up or page down to S-OVP, S-OCP or S-OPP place to set over-voltage value , over-current value and over-power value correspondingly; when the value is up to the setting value, output will be closed ; and there is a prompt on right of screen . And then press shortly the coding potentiometer to enter into the status of adjusting the numerical value you want to adjust. Turn coding potentiometer to adjust the numerical value. If you want to exit adjusting the numerical value, press shortly SET key.

Adjust the brightness of screen:
Page up or page down to B-LED, and then press shortly the coding potentiometer to enter into the status of adjusting the brightness of screen. Turn coding potentiometer to adjust the numerical value you need. If you want to exit adjusting the numerical value, press shortly SET key. There are six brightness levels of LCD screen, 0-5 level. Rank 0 is the darkest; rank 5 is the brightest. You can choose what you like.

Data setting and store the specified data group:
Page up or page down to M-PRE, and then press shortly the coding potentiometer to enter into the status of choosing the data groups. Turn coding potentiometer to choose the data group you need to view. Then the data group you need will be displayed. And then press the coding potentiometer to enter into status of changing output state. Turn coding potentiometer to choose ON or OFF. When choose ON, the data group is extracted and the output status remain the same. When choose OFF, the data group is extracted and the output is closed. If you want to exit choosing data set, press shortly SET key. Then press shortly V/↑or A/↓ to page up or page down to other place to adjust the data you need. After data setting done, keep pressing SET key more than 2s, all the data you set are automatically stored into the specified data group. In the same time, you can see the group number on the right of screen. At last you can press shortly SET key back to the main interface.

Set default boot open or close output:
Page up or page down to S-INI, and then press shortly the coding potentiometer to enter into the setting status. Set ON, default boot open; set off, default boot close.

Function Description

Open or close the output:
You can press ON/OFF key to open or close the output on any interface.

Lock the button to avoid wrong operation:
On the any interface, you can keep pressing coding potentiometer more than 2s, all buttons are locked. You can see the key lock icon on the right of screen. If you want to unlock all buttons, keep pressing coding potentiometer more than 2s, all buttons are unlocked. The key unlock icon will be displayed on the right of screen.

M0-M9 ten groups data group:
M0 group is the boot default data group. When you extract the data group you need, this data group will cover M0 data group and be automatically stored on M0 data group.

Extract Shortcut storage data group M1 or M2:
On the main interface, keep pressing V/↑or A/↓ more than 2s, you can extract Shortcut storage data group M1 or M2 quickly. In the same time the corresponding data group number will displayed on the right of the screen.

Extract the specified data group:
On the main interface, keep pressing SET key more than 2s, the sequence number of data group will be displayed on the right of the screen, you can turn coding potentiometer to choose data group you need. And then press shortly SET key, you can extract the specified data group you need.

Additional information

Weight 0.22 kg

Reviews

There are no reviews yet.